Product Description
FSP1200-50AAG is an industrial level of switching power supply. The power supply comes to offer the total power capacity up to 1200 Watts, and uses unique active PFC (Power Factor Correction) circuit design with its high-load electrical components, makes it to be perfectly used in an industrial environment. In addition, with its full range of input and output electrical features, the power supply is ideally the best choice for server, workstation, communication or any other automation applications to use. The product also complies with the latest safety and EMC standards, which is perfectly to meet various regulations worldwide.
DIMENSION: |
|
Dimension |
190mm(L) x 150mm(W) x
86mm(H) |
PRODUCT HIGHLIGHT: |
|
Efficiency Level |
80 Plus Gold |
Altitude |
5000M |
INPUT SPECIFICATION: |
|
Input Range |
90-264 Vac |
Input Frequency |
47-63 Hz |
Input Current |
115V@ 12.0 Amps-rms maximum
230V@ 6.0 Amps-rms maximum |
GENERAL SPECIFICATION: |
|
Effciency |
90% 230VAC |
Voltage |
+3.3V, +12V, +5V, +5SB: ±5% |
Regulation |
-12V: ±10% |
OUTPUT SPECIFICATION: |
|
Hold up Time |
115V/60Hz 17mSec.
Minimum@100% Load,
230V/50Hz 17mSec.
Minimum,@100% Load |
Ouput Voltage Regulation: |
+3.3Vdc output : +3.76 Vdc minimum, + 4.8Vdc maximum
+5Vdc output : +5.75 Vdc minimum, + 7.0Vdc maximum
+12Vdc output : +13.5 Vdc minimum, + 15.5Vdc maximum |
Output Rise Time |
115V-rms/230V-rms 5V
20ms Maximum
115V-rms/230V-rms 12V
20ms Maximum |
Ripple & Noise |
3.3V:50mV p-p
5V:50mV p-p
12V1:120mV p-p
-12V:120mV p-p
5Vsb:50mV p-p
|
ENVIRONMENTAL SPECIFICATION: |
|
TEMP.Range |
Storage Temperature: –
20°C to + 80℃ |
MTBF |
The power supply have a minimum predicted
MTBF(MIL-HDBK-217) of
100,000 hours of continuous
operation at 25℃, maximum-output load, and
nominal AC inout voltage
|
Note:
Maximum continuous total DC output power should not exceed 1200W.
Maximum continuous combined load on +3.3DC and +5VDC outputs shall not exceed 150W.
Ripple and noise measurements shall be made under all specified load conditions through a single pole low pass filter with 20MHz cutoff frequency. Outputs shall bypassed at the connector with a 0.1uF ceramic disk capacitor and a 10uF electrolytic capacitor to simulate system loading.